Fireboy automatic clean-agent fire extinguisher — FK-5-1-12 (vertical mount)

★★★★★4.8 / 5
€789,00
incl. VAT 25.5%

Made in GB

Fireboy automatic clean-agent fire extinguisher with FK-5-1-12 (Novec™ 1230) — total-flooding fire suppression for engine rooms and machinery spaces. The clean agent leaves no residue, won't damage electronics, and is the only system rated for occupied spaces.

  • Auto-activation at 79°C (175°F) + manual pull-cable for early discharge
  • 14 sizes — pick by your engine room volume (m³)
  • FK-5-1-12 is the EPA-approved next-gen agent (no ozone depletion, low GWP)
  • Vertical mount, factory-charged, includes pressure gauge and wall bracket

Sizing rule: Cylinder protected volume should match or exceed your engine room's net volume (m³). When in doubt, oversize one step — it's much cheaper than the boat. See sizing chart in tech specs below.


Select model
3.0 kg — protects 3.5 m³
€789,00
4.9 kg — protects 5.7 m³
€1.169,00
6.1 kg — protects 7.0 m³
€1.239,00
8.5 kg — protects 10.0 m³
€1.684,00
12.2 kg — protects 14.1 m³
€2.174,00
15.8 kg — protects 18.4 m³ (tall narrow)
€2.989,00
17.1 kg — protects 19.8 m³ (tall narrow)
€3.139,00
17.1 kg — protects 19.8 m³ (short wide)
€3.504,00
22.0 kg — protects 25.5 m³
€3.804,00
26.8 kg — protects 31.1 m³
€4.334,00
4.3 kg — protects 4.9 m³
€1.019,00
11.0 kg — protects 12.7 m³
€2.009,00
13.4 kg — protects 15.6 m³
€2.379,00
14.6 kg — protects 17.0 m³
€2.579,00

In stock — ships within 1–2 business days
Free shipping on orders over 100€ · Free returns within 14 days

Use cases

Engine room fire suppression — the only system
You can't fight an engine room fire with a handheld extinguisher — by the time you open the hatch, the fire roars from the oxygen rush. A clean-agent system extinguishes the fire BEFORE you open the hatch. This is non-negotiable for any boat with an enclosed engine room.
Insurance / certification requirement
Most marine insurers require an automatic engine-room fire system for boats over 8 m with enclosed engines. USCG, MED and ABYC certifications make this Fireboy line accepted by insurers worldwide. Without it, your premium is higher or coverage is denied.
Replacement for expired CO₂ or Halon systems
CO₂ is dangerous in occupied spaces (suffocation). Halon is banned (ozone depletion). FK-5-1-12 is the modern replacement — safe in occupied spaces, EPA-approved, electronic-safe. Drop-in replacement for old Halon/CO₂ systems.

Specifications

Load3.0 kg
Protects3.5 m³
DimensionsØ130 × 512 mm
Net weight8.5 kg
SuitsSmall engine box / sail boat aux
BrandFireboy / Xintex
AgentFK-5-1-12 (3M™ Novec™ 1230) — synthetic clean agent
ActivationAutomatic at 79°C (175°F) + manual pull-cable
MountVertical, includes wall bracket
Pressure indicatorBuilt-in gauge — visual charge check
Discharge time≤10 seconds (NFPA 2001)
Available sizes14 cylinders, 3.0 to 26.8 kg load (3.5 to 31.1 m³ protected)
CertificationsUSCG approved, ABYC compliant, IMO MED
Safe inOccupied spaces (unlike CO₂)
RefillRefillable by Fireboy-authorized service centres
Made inUSA / Latvia

Installation guide

1
Measure your engine room net volume
Net volume = L × W × H of the engine compartment, MINUS the volume of the engines, batteries, fuel/water tanks. As a rule, gross volume × 0.85 gets close to net. Round UP — never round down.
2
Pick the cylinder by protected volume
Pick a cylinder whose protected volume ≥ your engine room net volume. When in doubt, oversize one step — a 25 m³ engine room with a 19.8 m³ cylinder is under-protected. The extra €500 on a bigger cylinder is cheap insurance.
3
Mount vertically near the ceiling
Mount the cylinder upright (gauge up) high in the engine room, ideally near the ceiling — clean agent is denser than air and sinks into the engine space. Use the included wall bracket bolted into a structural member, not a thin bulkhead.
4
Plumb the manual pull-cable
Run the manual pull-cable from the cylinder to a visible location at the helm and at the cockpit entrance. Two pull points = early discharge from wherever you are when fire starts. Don't shortcut this — manual discharge saves boats.
5
Wire the engine shutdown loop
Most insurers require the engine to shut off when the system discharges (so the engine doesn't suck out the clean agent before it works). Wire the cylinder's microswitch into the engine kill loop. This is non-optional — check your policy.
6
Document and tag
Tag the install date on the cylinder. Inspect annually (visual check of pressure gauge, pull-cable freedom). FK-5-1-12 cylinders are factory-charged for 10 years — refill or replace before the date stamp expires.